Rocket RE Doppia at Sabah Coffee Co.: One Group Running Slow

← Back to My Bench

Sabah Coffee Co.5242 W 84th St, Bloomington, MN

Sabah Coffee Co.'s Rocket RE Doppia on the bar in Bloomington, pulling a weighed shot with customers lined up.
Sabah Coffee Co.'s Rocket RE Doppia on the bar in Bloomington, pulling a weighed shot with customers lined up.

The problem

Sabah had been open about two months on a new Rocket RE Doppia. The left group pulled great shots. The right one pulled long, weak, watery ones, and there was an out-of-order sign on it by the time I came in. Reprogramming the doses hadn’t fixed it.

What I found

I tested instead of guessing. I weighed shots on a scale, then ran free-flow water from each group with no portafilter. The right group ran about four times slower than the left, but both flowmeters counted the same. That ruled out the electronics and pointed to a physical restriction in the water path.

Inside the right group’s water path, the gicleur’s filter screen was choked. The café’s under-sink filter only fed the sink, so the machine was running on untreated water. A TDS meter read 148 ppm of dissolved minerals.

What I did

The result

Both groups pulling the same shot again. Even a brand-new machine needs its water path looked after, and the right test finds the fault before anyone starts buying parts.

Parts used

More photos

A shot pulling into a Sabah cup, with the group display counting the seconds.
A shot pulling into a Sabah cup, with the group display counting the seconds.
Sabah's Doppia the day I came in, with an out-of-order sign on the right group.
Sabah's Doppia the day I came in, with an out-of-order sign on the right group.
Top panel off the Doppia: the steam boiler, the group solenoids and the copper lines to each group.
Top panel off the Doppia: the steam boiler, the group solenoids and the copper lines to each group.
The brass blocks that feed each group on the Doppia, where the right group's water path was restricted.
The brass blocks that feed each group on the Doppia, where the right group's water path was restricted.
Testing Sabah's water with a TDS meter: 148 ppm of dissolved minerals.
Testing Sabah's water with a TDS meter: 148 ppm of dissolved minerals.
The filter under Sabah's sink. It fed the sink, not the espresso machine, so the Doppia was running on untreated water.
The filter under Sabah's sink. It fed the sink, not the espresso machine, so the Doppia was running on untreated water.
White mineral scale on a water fitting and its mesh screen, the kind of buildup that chokes the small jets inside.
White mineral scale on a water fitting and its mesh screen, the kind of buildup that chokes the small jets inside.

One group pulling different shots than the other?