Home espresso machineTwin Cities Metro, MN

The problem
This one came in for a routine tune-up: a drip at one fitting, and a slow weep into the drip tray the owner wasn’t sure was normal. It wasn’t.
What I found
On a long idle heat-up with no shots pulled, the expansion valve was dripping far faster than its normal bleed, and the boiler safety valve was venting steam on a plain heat cycle. Tracing the leak back, water had been running inside the machine onto the electrical section at the top of the boiler.
The solid-state relay and a terminal block with zero ingress protection both tested with failing insulation to the chassis. The heating element told the same story: its resistance across the terminals looked normal, but it failed the insulation test to the chassis. A plain resistance check would have passed it.
What I did
- Replaced the solid-state relay and the terminal block.
- Re-terminated the cracked crimps in the harness.
- Dealt with the element’s failed insulation.
- Renewed the group gasket and shower screen.
- Serviced the valves and the pressure side once the machine was safe to power up.
The result
“A drip” was the symptom. The real job was finding out where the water was going. Since this machine, every heating element on my bench gets a 500-volt insulation test, not just a resistance check.
Parts used
- Carlo Gavazzi RM1A23A25 solid-state relay
- Terminal block
- E61 group gasket (8.5mm) and shower screen
Water inside your machine, or a breaker that trips?