Quick Mill Anita Evo: A “Small Drip” That Was an Electrical Fault

← Back to My Bench

Home espresso machineTwin Cities Metro, MN

The Quick Mill Anita Evo back in service after the water damage repair.
The Quick Mill Anita Evo back in service after the water damage repair.

The problem

This one came in for a routine tune-up: a drip at one fitting, and a slow weep into the drip tray the owner wasn’t sure was normal. It wasn’t.

What I found

On a long idle heat-up with no shots pulled, the expansion valve was dripping far faster than its normal bleed, and the boiler safety valve was venting steam on a plain heat cycle. Tracing the leak back, water had been running inside the machine onto the electrical section at the top of the boiler.

The solid-state relay and a terminal block with zero ingress protection both tested with failing insulation to the chassis. The heating element told the same story: its resistance across the terminals looked normal, but it failed the insulation test to the chassis. A plain resistance check would have passed it.

What I did

The result

“A drip” was the symptom. The real job was finding out where the water was going. Since this machine, every heating element on my bench gets a 500-volt insulation test, not just a resistance check.

Parts used

Water inside your machine, or a breaker that trips?

Next on the bench: Rocket Appartamento That Kept Shutting Itself Off · See all the machines