Ginkgo Coffeehouse, GardenView347 Smith Ave N, St. Paul, MN

The problem
Ginkgo runs this La Cimbali M34 two-group at their café in the GardenView Medical Building in St. Paul. They called about a leak and a water-temperature complaint.
What I found
The display was already asking for maintenance. The steam valve knob had broken off its clip, leaving the bare valve stem for the baristas to turn. Under the cup tray, the drain box was holding water because the drain hose was blocked, and spent coffee grounds had built up around the flowmeters, the fill solenoid and the control box wiring.
What I did
- Traced the leak on site.
- Cleared the blocked drain hose and fitted a new hose gasket.
- Replaced the broken clip on the steam valve knob.
- Checked the water filtration and recommended a new cartridge and a softener.
The result
Back in service the same visit. A busy café can’t sit closed waiting on a part, so on-site work is about getting them running before I leave.
Parts used
- Drain hose gasket
- Steam valve knob clip